Nature of Source Flow: | Active Inverter |
---|---|
Certification: | CCC, ISO9001, RoHS, CE |
Output Power: | 5kw |
Grid Type: | off-Grid Inverter |
Output Type: | Single |
Circuit Topologies: | Full-Bridge Type |
Customization: |
---|
Suppliers with verified business licenses
Model | AUP4850-EU-80-H | ||||||
Battery Input | |||||||
Battery type | Sealed,FLood,GEL,LFP,Ternary | ||||||
Rated Battery Input Voltage | 48V ( Minimum Startup Voltage 44V) | ||||||
Hybrid Charging Maxi mum Charging Current | 80A | ||||||
Battery Voltage Range | 40Vdc~60Vdc ± 0.6Vdc(Undervoltage Warning/Shutdown Voltage/ Overvoltage Warning/Overvoltage Recovery...) | ||||||
Solar Input | |||||||
Maximum PV Open-circuit Voltage | 500Vdc | ||||||
PV Working Voltage Range | 120-500Vdc | ||||||
MPPT Voltage Range | 120-450Vdc | ||||||
Maximum PV Input Current | 22A | ||||||
Maximum PV Input Power | 5500W | ||||||
Maximum PV Charging Current | 80A | ||||||
AC Input(generator/grid ) | |||||||
Mains Maximum Charging Current | 60A | ||||||
Rated Input Voltage | 220/230Vac | ||||||
Input Voltage Range | UPS Mains Mode:(170Vac~280Vac)±2% APL Generator Mode:(90Vac~280Vac)±2% | ||||||
Frequency | 50Hz/ 60Hz (Automatic Detection) | ||||||
Mains Charging Efficiency | > 95% | ||||||
Switch Time (bypass and inverter) | 10ms(Typical Value) | ||||||
Maximum Bypass Overload Current | 40A | ||||||
AC Output | |||||||
Output Voltage Waveform | Pure Sine Wave | ||||||
Rated Output Voltage (Vac) | 230Vac (200/208/220/240Vac) | ||||||
Rated Output Power (VA) | 5000 (4350/4500/4750/5000) | ||||||
Rated Output Power(W) | 5000 (4350/4500/4750/5000) | ||||||
Peak Power | 10000VA | ||||||
On-load Motor Capacity | 4HP | ||||||
Output Frequency Range(Hz) | 50Hz±0.3Hz/60Hz±0.3Hz | ||||||
Maximum Efficiency | >92% | ||||||
No-load Loss | Non Energy-saving Mode: ≤50W Energy-saving Mode:≤25W (Manual Setup) | ||||||
General | |||||||
Number of parallel/split phases | 1-6PCS | ||||||
Certificate | CE(IEC62109-1)/CETL(UL 1741 C22.2 NO.107.1) | ||||||
EMC Certification Level | EN61000, C2 | ||||||
Working Temperature Range | -10°C ~ 55°C | ||||||
Storage Temperature Range | -25°C ~ 60°C | ||||||
Humidity Range | 5% to 95%(Conformal Coating Protection) | ||||||
Dimensions | 426mm*322mm*124mm | ||||||
Weight (KG) | 10.5 | ||||||
Warranty | 1 Year |
FAQ For More About Austa Solar |
1.Are you a factory or trading company? We are a factory of osda solar group which located in ningbo,china, which is two hours away from shanghai.Welcome to visit us. 2.How many employees in your factory? There are about 350 people in our factory, including 80 management staff, 260 workshop workers and more than 10 logistics staff. 3.What about the quality management pls? we insist on product development, quality management and supply chain management together to provide highly competitive services to our customers.and we won various awards in the industry the last 10 years, while OEM for top 5 domestic inverters brands 4.What is your advantage? a.Within 7 days delivery; b. More convenient terms of payment, more flexible financial solutions; c. Exceeds 5 years product design life among the industry standards ; d. Premium supply chain management system to ensure market competitiveness, c. Engineers own ten years of a large factory R&D experience. 5.What is your sample policy? We welcome you to test our quality through sample. sample will be prepared and sent out within seven working days after specification is confirmed, track no.will be noticed the next and we will follow up with service about follow-up testing. |