Model | AU-3P4K4G-HE-15A | AU-3P5K4G-HE-15A | AU-3P6K4G-HE-15A | AU-3P8K4G-HE-15A | AU-3P10K4G-HE-15A | AU-3P12K4G-HE-15A |
PV Input | ||||||
Max. Input Power (kW) | 6.0 | 7.5 | 9.0 | 12.0 | 15.0 | 18.0 |
Start-up Voltage (V) | 135 | 135 | 135 | 135 | 135 | 135 |
Max. DC Input Voltage (V)* | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 |
Rated DC Input Voltage (V) | 620 | 620 | 620 | 620 | 620 | 620 |
MPPT Voltage Range(V) | 120-950 | 120-950 | 120-950 | 200-950 | 200-950 | 200-950 |
No. of MPPT Trackers | 2 | 2 | 2 | 2 | 2 | 2 |
No. of DC Inputs per MPPT | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 |
Max. Input Current (A) | 15/15 | 15/15 | 15/15 | 15/15 | 15/15 | 15/15 |
Max. Short-circuit Current (A) | 20/20 | 20/20 | 20/20 | 20/20 | 20/20 | 20/20 |
Battery Side | ||||||
Battery Type | Lithium Battery (with BMS) | |||||
Battery Voltage Range (V) | 135-750 | |||||
Max. Charge/Discharge Current (A) | 25/25 | |||||
Grid Side | ||||||
Rated Output Power (kW) | 4.0 | 5.0 | 6.0 | 8.0 | 10.0 | 12.0 |
Max. Output Apparent Power (kVA) | 4.4 | 5.5 | 6.6 | 8.8 | 11.0 | 13.2 |
Max. Intput Apparent Power (kVA)** | 8.0 | 10.0 | 12.0 | 16.0 | 16.5 | 16.5 |
Max. Charging Power of Battery (kW) Rated AC Voltage (V) | 4.0 | 5.0 | 6.0 | 8.0 | 10.0 | 12.0 |
Rated AC Voltage (V) | 3L/N/PE; 220/380V; 230/400V; 240/415V | |||||
Rated AC Frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
Max. Output Current (A) | 6.7 | 8.3 | 10.0 | 13.3 | 16.5 | 20.0 |
Powor Factor | 0.8 leading ...0.8 lagging | |||||
Max. Total Harmonic Distortion | <3% @Rated output power | |||||
DCI | <0.5%In | <0.5%In | <0.5%In | <0.5%In | <0.5%In | <0.5%In |
Back-up Side | ||||||
Rated Output Power (kW) | 4.0 | 5.0 | 6.0 | 8.0 | 10.0 | 12.0 |
Max. Output Apparent Power (kVA) | 4.4 | 5.5 | 6.6 | 8.8 | 11.0 | 13.2 |
Max. Output Current (A) | 6.7 | 8.3 | 10.0 | 13.3 | 16.5 | 20.0 |
UPS Switching Time | <10ms | <10ms | <10ms | <10ms | <10ms | <10ms |
Rated Output Voltage (V) | 3L/N/PE; 220/380V; 230/400V; 240/415V | |||||
Rated Output Frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
Peak Out Apparent Power (KVA)*** | 8, 60s | 10, 60s | 12, 60s | 16, 60s | 20, 60s | 20, 60s |
Voltage Harmonic Distortion | < 3% @Linear load | |||||
Efficiency | ||||||
Max. Efficiency | 98.1% | 98.1% | 98.1% | 98.2% | 98.2% | 98.2% |
European Efficiency | 97.3% | 97.3% | 97.3% | 97.4% | 97.4% | 97.4% |
Compliance | IEC/EN 62109, IEC/EN 61000, EN50549-1, TOP Generator Type A, VDE-AR-N-4105 | |||||
Protection | General Data | |||||
DC Reverse Polarity Protection | Integrated | Over Voltage Category | PV: || ; Main: ||| | |||
Battery Input Reverse Connection Protection | Integrated | Dimensions (WxHxD mm) | 534×418×210 | |||
Insulation Resistance Protection | Integrated | Weight (KG) | 26 | |||
Surge Protection | Integrated | Protection Degree | IP65 | |||
Over-temperature Protection | Integrated | Standby Sell-consumption (W) | <15 | |||
Residual Current Protection | Integrated | Topology | Transformerless | |||
Islanding Protection | Integrated | Operatng Temperature Range (ºC) | -30~60 | |||
AC Over-voltage Protection | Integrated | Relative Humidity (%) | 0~100 | |||
Overload Protection | Integrated | Operating Altitude (m) | 3000 (>3000m derating) | |||
AC Short-circuit Protection | Integrated | Cooling | Natural Convection | |||
Noise Level (dB) | <25 | |||||
Display | OLED & LED | |||||
Communication | CAN, RS485, WiFi/LAN (Optional) | |||||
* Max. operating DC voltage is 950V, max. withstanding DC voltage is 1000V ** Max. apparent power from the grid means the maximun power from the utility grid used to satisfy the backup and charge the battery *** The output power will exceed the rated value only when the power in the PV array is sufficient, and the dyration of the overload is related to the overload power |
||||||